Check oil level & leakage: Keep lubricating oil within standard scale; inspect pipelines for oil and air leakage.
Drain condensed water: Drain water from air tanks and separators every week; drain every 2-3 days in high temperature and humid environments to avoid component corrosion.
Monitor meters & operating sound: Normal exhaust temperature ≤110℃. Stop the machine immediately to troubleshoot abnormal noise or excessive vibration.
Clean heat dissipation system: Blow dust off the radiator with compressed air weekly to prevent high-temperature shutdown.